SONY HBD-E780W/E980W/E985W BLU RAY SERVICE TIPS

SONY HBD-E780W/E980W/E985W

BLU RAY PLAYER

SERVICE TIPS

HOW TO OPEN THE TRAY WHEN POWER SWITCH TURN OFF
Note 1: After the left panel (E1) is removed, this work is done.
Note 2: Please prepare the thin wire (clip etc. processed to the length of 8 cm or more).
Remove the left panel (E1).
(Illustration of disassembly is omitted.)
Insert the clip etc. processed to the length of 8 cm or more in the hole on the side of the chassis and push.
Note :Push after it inserts it in this hole well.

RELEASING THE DISC TRAY LOCK
The disc tray lock function for the antitheft of an demonstration
disc in the store is equipped.
Releasing Procedure:
1. Press the [POWER] button to turn on the system.
2. Touch the [FUNCTION] sensor to select “BD/DVD”.
3. Touch the [STOP] and [EJECT] sensors simultaneously and hold down
unit “DEMO OFF” displayed on the fluorescent indicator tube
(around 5 seconds).
Note: When “DEMO LOCK” is displayed, the disc tray lock is not released by turning power on/off with the [POWER] button.
Optical device (KEM-460AAA) replacement
Procedure:
1. Remove the INSULATOR (4 pieces) and broken optical device (KEM-470AAA) from LOADING ASSY.
2. Take photo of the barcode on new optical device (KEM- 470AAA) bottom side by digital camera.
3. Assemble the INSULATOR (4 pieces) to new optical device (KEM-470AAA), f x (Torque value: 2 kgf) it to LOADING ASSY with screw, and assemble this unit.
4. Drag & drop the taken photo by step 2 to “BDPRDec.exe”, and make the text data (File name: BuData.txt).
5. Save the text data to USB memory.
6. Connect USB memory with rear USB connector on this unit, and turn the power on.
7. Press the [FUNCTION] button on the remote commander to select “BD/DVD”.
8. Press the buttons on the remote commander in order of [DISPLAY], [0], [2], [1], [SUBTITLE], and enter the service mode.
9. Press the buttons on the remote commander in order of [8], [1], [ENTER], and execute “[1] Drive OP data Write”.
10. Turn the power off after writing the OP data.
11. Turn the power on, and enter the service mode again.
12. Press the buttons on the remote commander in order of [8], [7], [3], [ENTER], and the dIOP value is displayed.
13. Conf rm value is the following specification value, and turn the power off.
Specification value:
BD : ±3 mA
DVD/CD : ±3 Ma
14. Turn the power on, confirm playback performance of the BD (BLX-104)/DVD (HLX-513)/CD (HLX-A1).
15. Completely assemble this unit, and complete the repair.
COLD RESET
The cold reset clears data except BD/DVD data stored in the RAM to initial conditions. Execute this mode when returning the unit to the customers.
Procedure:
1. Press the [POWER] button to turn the power on.
2. Touch the [STOP] and [VOL –] sensors simultaneously and hold down (around 5 seconds).
3. The message “RESET” appears on fluorescent indicator tube, then becomes standby states.
DEMO MODE
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [Z] sensor is touched. The message “DEMO LOCK” will be displayed on the fluorescent indicator tube.
Procedure:
1. Press the [POWER] button to turn the power on.
2. Touch the [FUNCTION] sensor to select the “BD/DVD”.
3. Touch the [STOP] and [EJECT] sensors simultaneously and hold down until “DEMO LOCK” or “DEMO OFF” displayed on the fluorescent indicator tube (around 5 seconds).
Releasing method:
Touch the [STOP] and [EJECT] sensors simultaneously and hold down until “DEMO OFF” displayed on the f uorescent indicator tube (around 5 seconds).
PANEL TEST
Procedure:
1. Press the [OWER ] button to turn the power on.
2. Press button in order of the [DISPLAY]
[0] [0] [1] [SUBTITLE] on the remote commander (Make the interval when each button is pressed within two seconds).
3. All segments in f uorescent indicator tube are lighted up. And half segments in f uorescent indicator tube are lighted up, others half segments in f uorescent indicator tube are lighted up, then all segments in f uorescent indicator tube are lighted up. This operation is repeated.
4. When all segments in f uorescent indicator tube are lighted up in the state of step 3, press the [VOL +] button on the remote commander and model information is displayed on the fluorescent indicator tube. Each time the [VOL +] button on the remote commander is pressed, the display changes from destination information, STR version in this order, and returns to the model information display. Each time the [VOL –] button on the remote commander is pressed, the version and date are switched.
5. In the state of step 3, press the [FUNCTION] button on the remote commander and “K 0” is displayed on the fluorescent indicator tube. “K 0” value increases whenever a button or sensor on the unit is pressed. However, once a button or sensor has been pressed, it is no longed taken into account. All button and sensors on the unit are pressed, “OK” and “K 7” are alternately displayed on the fluorescent indicator tube.
Releasing method:
To release from this mode, press the [POWER] button.
FACTORY INITIALIZE
Return all of the unit setting to their factory defaults. Note 1: Disconnect the following connections when you use this mode.
• Front USB
• Rear USB
• LAN
• HDMI IN 1
• HDMI IN 2
Note 2: The operation in this mode must use a remote commander and TV monitor.
Procedure:
1. Press the [POWER] button to turn the power on.
2. Press the [HOME] button on the remote commander, and the home menu is displayed.
3. Select “Setup”
“Resetting”, and press the [ ] button on the remote commander.
4. Select “Initialize Personal Information”, and press the [ ENTER ] button on the remote commander.
5. Select “OK”, and press the [ENTER ] button on the remote commander
6. The message “Close” appears, and press the [ENETER ] button on the remote commander.
7. Select “Reset to Factory Default Settings”, and press the [ENTER ] button on the remote commander.
8. Select “All Settings”, and press the [ENETER] button on the remote commander.
9. Select “Start”, and press the [ENTER ] button on the remote commander.
10. Initialization ends when the message “WELCOME” on the fluorescent indicator tube disappears.